uk german france spain china

Latest News Home Page

lower

RPI re-launch the i72 Angle Reference Standard

Monday, November 14th, 2011

The i72 Angle reference standard is now available to all Laser Interferometer and Autocollimator manufacturers, calibration laboratories, and rotary axis OEM’s
The i72 is a compact high accuracy positioning system for use [...]

moreinfo

AGENTS NETWORK

Find one of our partners in your country click here >

QD12-07-C – Flatness of The Table Top Surface

The flatness check determines the distance ‘t’ between two parallel planes within which the surface lies. The surface must be flat or concave.

Methods vary according to table size. Generally comparisons are made against a master straight edge, which is supported above the surface on, or close, to its minimum deflection points. Dial gauges or slip gauges are used for this purpose. A set of readings is taken across a diagonal, which would be repeated at a number of other diagonals.

A blue check with a master flat surface provides an immediate visual guide to the form.

Downloads
QD12-07-C
Go back


Web design Exeter by: